WeChat: +86.13328318872 | Home | InSite Search | About Us | Contact Us |
![]() |
|
![]() |
![]() |
|
Pimpex@RPM supplies ePTFE masks, disposable masks, microfiltration membrane flat protective masks for the protections from Coronavirus COVID-19. |
Comparison of ePTFE Protective Masks with Other Conventional Masks | ||||
Type | ePTFE Protective Masks | N95 Masks | General Surgical Masks | Activated Carbon Masks |
Filter | ePTFE | Multi-Layers Electrostatic Meltblown Cloth |
Electrostatic Meltblown Cloth | Activated Carbon |
Filtration Efficiency | ≥98% | 95% | 30%-40% | 30%-40% |
Breathability | Excellent | Poor | Excellent | Excellent |
PM2.5 Protection | Excellent | Excellent | Poor | Poor |
Pollen / Dust Protection | OK | OK | Common | Common |
Oil Mist / Alcohol Protection | OK | NO | NO | NO |
Microbiological Protection | OK | OK | NO | NO |
Acutal Measured Datas of ePTFE Protective Masks |
|||
Item | Standard Data | Actual Measured Data | |
Filtration Efficiency | NaCl Particulate Filtration Efficiency | Filtration Efficiency: ≥95.0% (KN95 level) | ≥98.0% |
≥96.0% Pretreatment Status of Temperature and Humidity | |||
Respiratory Resistance | Inhalation Resistance | ≤350 | <100 |
Expiratory Resistance | ≤250 | <80 |
Not Afraid of Water and Disinfectant, Just Because of Having High-Tech "Core" The ePTFE microporous membrane masks made of non-perfluorooctanoic acid (PFOA) PTFE resin have been tested by the national authority, and the filtration efficiency has reached 99.2% (N95, KN95 masks level). The inhalation resistance is less than 15% of the standard limit, which can effectively achieve a good effect of impermeable to water, filtering PM2.5, and preventing microorganisms and bacteria from entering the body. |
Inspection and Testing Items (Unit of Measurement) [Sample identification] |
Test Methods | Standard Value and Tolerance | Inspection Test Results | Determination |
NaCl Particulate Matter Filtration Efficiency | GB 2626-2006 6.3 Air Flow: 85L/min Aerosol Particles: NaCl Aerosol Concentration: 15mg/m3 Temperature: 23.1℃ Relative Humidity: 36.5% |
Filtration Efficiency (%): ≥95.0 (KN95 Level) | Filtration Efficiency (%): Untreated Sample 1# 99.960 2# 98.880 3# 99.091 4# 98.990 5# 98.900 6# 99.891 7# 99.467 8# 99.120 9# 98.900 10# 99.411 Temperature and Humidity Pretreated Samples 1# 99.899 2# 98.904 3# 98.800 4# 99.014 5# 99.048 |
Pass |
Inhalation Resistance | GB 2626-2006 6.5 | ≤350 | Untreated Sample 1# 93.5 2# 89.1 Temperature and Humidity Pretreated Samples 1# 71.0 2# 74.8 |
Pass |
Expiratory Resistance | GB 2626-2006 6.6 | ≤250 | Untreated Sample 1# 60.8 2# 57.1 Temperature and Humidity Pretreated Samples 1# 47.2 2# 51.3 |
Pass |
![]() Application on Coronavirus COVID 19 Protection |
![]() Application on Haze Weather Protection |
![]() Application on Industrial Dusts Protection |
![]() Application on Pollen Allergy Protection |
||
Copyright © Pimpex@RPM Since 2002 www.gzqlh.com Sitemap XIAMEN RPM IMP.&EXP. CO.,LTD. |